Troubleshooting - Flow Chart - Recirculation Control (cont'd)
15-13flowchartFlow Chart - Recirculation Control (cont'd)
1
(From page 15-12)
2
Connect the GRN/RED and GRN/WHT terminals to the body ground using a jumper wire. Turn the ignition switch ON.
3
Does the motor run all the time?
NO
Replace the recirculation control motor.
YES
4
Turn the ignition switch OFF. Remove the heater control panel and disconnect the 13P connector.
5
Connect the GRN/WHT and GRN/RED terminals to BLK terminal using a jumper wire. Turn the ignition switch ON.
6
Does the motor run all the time?
YES
Replace the heater control panel.
NO
7
Check for continuity between the BLK terminal to body ground.
8
Is there continuity?
NO
Repair the poor ground (G201) or open in BLK wire between the heater control panel and blower.
YES
Repair open in GRN/RED or GRN/WHT between the heater control panel and blower.