Cigarette Lighter - Circuit Diagram / Cigarette Lighter Relay Test
16-121wiring diagramCigarette lighter relay fitted on KQ model only; 'Except KQ model' branch feeds the cigarette lighter directly. Bracketed grounds (G201/G401) apply to RHD.
Circuit Diagram
Wiring Schematic
Components (14)
BATTERYMAIN FUSE BOXNo.31 (60A)No.32 (50A)No.33 (40A)IGNITION SWITCH (BAT-B, ACC)DASH FUSE BOXNo.17 (10A)No.12 (15A)CIGARETTE LIGHTER RELAY (KQ model)CIGARETTE LIGHTERG301G201 (RHD)G401
Connections (10)
BATTERY
BATTERY:+MAIN FUSE BOXWhite
No.31 (60A)
No.31 (60A)IGNITION SWITCH (BAT-B, ACC):BAT-BWhite with Black stripe
No.33 (40A)
No.33 (40A)DASH FUSE BOX:No.12 (15A)White with Red stripe
IGNITION SWITCH (BAT-B, ACC)
IGNITION SWITCH (BAT-B, ACC):ACCDASH FUSE BOX:No.17 (10A)White with Red stripe
No.17 (10A)
No.17 (10A)CIGARETTE LIGHTER RELAY (KQ model):CYellow with Red stripe
No.12 (15A)
No.12 (15A)CIGARETTE LIGHTERWhite with Blue stripe
CIGARETTE LIGHTER RELAY (KQ model)
CIGARETTE LIGHTER RELAY (KQ model):ACIGARETTE LIGHTERWhite with Blue stripe
CIGARETTE LIGHTER RELAY (KQ model):BCIGARETTE LIGHTERWhite with Blue stripe
CIGARETTE LIGHTER RELAY (KQ model):DG301Black
CIGARETTE LIGHTER
CIGARETTE LIGHTERG301??
NOTE
( ) : RHD. Ground designations shown as G301 [G201] and G401 [G401]; bracketed values apply to RHD.
Cigarette Lighter Relay Test
There should be continuity between the A and B terminals when the battery is connected to the C and D terminals.
There should be no continuity when the battery is disconnected.