Integrated Control Unit (With Daytime and Dim-Dip Light) - Input Test (cont'd)
16-88spec tableWiper System ground cause uses RHD-alternate ground points in brackets, ( ): RHD.
Input Test (cont'd)
Wiper System:
1
TerminalBLK
Test conditionUnder all conditions.
Test: desired resultCheck for continuity to ground: should be continuity.
Possible cause (if result is not obtained)• Poor ground (G301, G401 [G201, G401]).
2
TerminalBLU/WHT1 and BLU/WHT2
Test conditionWiper switch OFF or INT and wiper blades in park position.
Test: desired resultCheck for continuity between the BLU/WHT1 and BLU/WHT2 terminals: should be continuity.
Possible cause (if result is not obtained)• Faulty wiper switch. • Faulty wiper motor. • An open in the wire.
3
TerminalGRN
Test conditionIgnition switch ON and wiper switch INT
Test: desired resultCheck for voltage to ground: should be battery voltage.
Possible cause (if result is not obtained)• Blown No.13 (15A) fuse. • Faulty wiper switch. • An open in the wire.
( ): RHD
Light-on Warning System:
1
TerminalBLK
Test conditionUnder all conditions.
Test: desired resultCheck for continuity to ground. should be continuity.
Possible cause (if result is not obtained)• Poor ground (G201, G401). • An open in the wire.
2
TerminalRED/BLK
Test conditionLighting switch ON.
Test: desired resultCheck for voltage to ground: should be battery voltage.
Possible cause (if result is not obtained)• Blown No.8 (10A) fuse. • Faulty lighting switch. • An open in the wire.
3
TerminalYEL
Test conditionIgnition switch ON.
Test: desired resultCheck for voltage to ground: should be battery voltge.
Possible cause (if result is not obtained)• Blown No.1 (10A) fuse. • An open in the wire.
4
TerminalGRN/RED
Test conditionPassenger door open.
Test: desired resultCheck for continuity to ground: should be continuity. NOTE: Before testing remove No.12 (15A) fuse.
Possible cause (if result is not obtained)• Faulty passenger door switch. • An open in the wire.
5
TerminalGRN/BLU
Test conditionDriver door open.
Test: desired resultCheck for continuity to ground: should be continuity.